
dIXEL
Operating Instructions
cod. 1592017410
1592017410 XLH360 GB r1.0 15.04.2005.doc XLH360 11/16
10.5 HEATING RELAY SAFETY (i1F=Ht)
With i1F=Ht as soon as the digital input is activated for “did” time heating relay is disabled.
The alarm will stop as soon as the digital input is de-activated.
10.6 DIGITAL INPUTS POLARITY
The digital input polarity depends on the “i1P” parameters. CL : the digital input is activated by closing the contact; OP : the digital input is activated
by opening the contact
11. INSTALLATION AND MOUNTING
The temperature range allowed for correct operation is 0 - 60 °C. Avoid places subject to strong vibrations, corrosive gases, excessive dirt or
humidity. The same recommendations apply to probes. Let the air circulate by the cooling holes.
Thanks to the case XLH360. See the following instructions for details.
A BC
D E
GF
FIG. 1
A
B
C
G
F
D
FIG. 2
87
230
M
A
X
3
7
210
130
120
M
A
X
2
8
H
I
FIG. 3
Comentários a estes Manuais